Home / Insights / Impeller Balance and Runout: The Spec to Give Your Machinist
INSIGHTS

Impeller Balance and Runout: The Spec to Give Your Machinist

Give your machinist three numbers: the balance grade, the runout limit and the test speed. How to read the report.

The three numbers

Balance grade (for example G2.5), runout limit (for example 0.05 mm) and the test speed. Without all three, the report does not prove the rotor is safe.

How to read the report

A dimensional report that only lists the balance weight without the runout is not complete. Ask for the runout on the same face as the balance reference.

Related parts

Impellers & Turbine Rotors New
Aerospace & Marine Impellers

Impellers & Turbine Rotors

5-axis machined impellers, turbine rotors and propellers for aerospace and marine use.

Tolerance ±0.02 mm MOQ 1 pc Lead time 15–25 days
View

Have a part to machine?

Send your drawing and receive a manufacturability review plus firm pricing within 24 hours.